Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
Seiceáil Slán Ráthaithe

Bronntanas Saor in Aisce
Fáilte go Roymall, do shuíomh gréasáin gairmiúil chun bronntanais ollmhargaidh préimhe a cheannach. Táimid thar a bheith buíoch as do thacaíocht, agus ba mhaith linn ár mbuíochas a chur in iúl trí bhlas breise spraoi a chur le do cheannacháin. Nuair a cheannaíonn tú linn, ní hamháin go mbaineann tú taitneamh as táirgí ar ardchaighdeán a fheabhsaíonn do stíl mhaireachtála, ach gheobhaidh tú bronntanas saor in aisce eisiach le gach ordú a chuirfidh tú. Réidh chun iniúchadh a dhéanamh ar ár mbailiúchán agus na bronntanais foirfe a aimsiú? Déan iniúchadh ar ár rogha earraí ollmhargaidh préimhe, cuir d'ordú, agus bí ag súil le spraoi do bhronntanais saor in aisce ag teacht in éineacht le do cheannach.Polasaí Loingseoireachta
Oibreoimid go dian chun earraí a sheachadadh chugat tar éis d'orduithe a fháil agus a chinntiú go sroicheann siad slán sábháilte. Soláthrófar sonraí seachadta i do ríomhphost deimhnithe.I bhformhór na gcásanna, déantar orduithe a phróiseáil laistigh de 2 lá. Faoi imthosca speisialta, déanfar moill air mar seo a leanas: Nuair a chuireann tú ordú Dé Sathairn, Dé Domhnaigh nó laethanta saoire poiblí, déanfar moill 2 lá air.De ghnáth, teastaíonn 5-7 lá oibre (Dé Luain go Dé hAoine) gan a bheith faoi thionchar moill eitilte nó tosca comhshaoil eile.Toisc go bhfuil ár seirbhís loingseoireachta ar fud an domhain, beidh amanna seachadta ag brath ar do shuíomh, mar sin d'fhéadfadh sé go mbeadh cúpla uair ag teastáil agus fan go foighneach má tá tú i gceantair nó tíortha iargúlta.1. Polasaí Fillte & Malartaithe
Glacaimid le míreanna a ceannaíodh ar roymall.com amháin. Má cheannaíonn tú ónár ndáileoirí áitiúla nó miondíoltóirí eile, ní féidir leat iad a fhillt orainn. Ní ghlactar le míreanna díolacha deiridh nó bronntanais saor in aisce le fillt.Chun bheith incháilithe le fillt, ní mór do mhír a bheith gan úsáid agus sa chéad chaoi a fuair tú í. Ní mór í a bheith sa phacáistiú bunaidh freisin.Tar éis treoracha fillte a fháil uainn, déan do mhíreanna fillte a phacáistiú agus do phacáiste a scaoileadh ag oifig an phoist áitiúil nó ag seachadóir eile.Déanfaimid do mhír fillte nó malartaithe a phróiseáil laistigh de 3-5 lá oibre tar éis dúinn í a fháil. Déanfar an t-aisíoc a phróiseáil agus a chreidiúint go huathoibríoch chuig do bhunmhodh íocaíochta.Ní féidir aon fhillt nó malartuithe a ghlacadh má táirgeadh an táirge go saincheaptha, lena n-áirítear méid saincheaptha, dath saincheaptha, nó cló saincheaptha.An bhfuil cabhair bhreise uait, déan teagmháil linn. service@roymall.com nó Whatsapp: +8619359849471
2. Polasaí Aisíocaíochta
Gheobhaidh tú aisíoc iomlán nó creidmheas siopa 100% tar éis dúinn an pacáiste fillte a fháil agus a sheiceáil. Déanfar an t-aisíoc a phróiseáil agus a chreidiúint go huathoibríoch chuig do bhunmhodh íocaíochta.Tabhair faoi deara nach bhfuil costais loingseoireachta agus aon dleachtanna nó táillí incháilithe le haghaidh aisíocaíochta. Ní féidir na costais loingseoireachta breise a aisíoc nuair a sheoltar an pacáiste. Tá tú freagrach as na táillí seo a íoc agus ní féidir linn iad a aisíoc nó a aisíoc, fiú má fhilltear an t-ordú ar ais chugainn.Nuair a fhaighimid agus a dheimhnímid do mhír fillte, seolfaimid ríomhphost chugat chun a chur in iúl duinn go bhfuairimid do mhír fillte. Cuirfimid in iúl duit freisin faoi cheadú nó diúltú d'aisíocaíocht.Má tá aon fhadhb agat maidir leis an bpróiseas aisíocaíochta, déan teagmháil linn. service@roymall.com nó Whatsapp: +8619359849471Feature:
200/100/70MHz bandwidths
1GSa/s Real Time sample rate
Large (7.0-inch) color display, WVGA(800x480)
Record length up to 40K
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard
Multiple automatic measurements
Four math functions, including FFTs standard
Provides software for PC real-time analysis
Model
DSO5102P
Acquisition
Sample Rate
Real-Time Sample: 1GS/s
Acquisition Modes
Normal
Normal data only
Peak Detect
High-frequency and randon glith capture
Average
Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling
AC, DC, GND
Inputs Impendance
1Mu03a9u00b12%u201620pFu00b13pF
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factor
1X, 10X, 100X, 1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10u00d7), Installation Category;
CAT III: 150VRMS (1u00d7);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.Horizontal System
Sample Rate Range
500MS/s--1GS/s
Waveform Interpolation
(sin x)/x
Record Length
40K
SEC/DIV Range
4ns/div to 40s/div
Sample Rate and
Delay Time Accuracyu00b150ppm(at over any u22651ms time interval)
Position Range
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400sTime Measurement Accuracy
(Full Bandwidth)Single-shot, Normal mode:u00b1 (1 sample interval +100ppm u00d7 reading + 0.6ns);
>16 averages:u00b1 (1 sample interval + 100ppm u00d7 reading + 0.4ns);
Sample interval = s/div u00f7 200Vertical System
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 10V/div
Bandwidth
100MHz
Rise Time at BNC( typical)
3.5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, u00b1400mV; 50mV/div to 200mV/div, u00b12V
500mV/div to 2V/div, u00b140V; 5V/div, u00b150VMath
+, -, *, /, FFT
FFT
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample pointBandwidth Limit
20MHz
Low Frequency Response (-3db)
u226410Hz at BNC
DC Gain Accuracy
u00b13% for Normal or Average acquisition mode, 5V/div to 10mV/div;
u00b14% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy,
Average Acquisition ModeWhen vertical displacement is zero, and N u226516:u00b1 (3% u00d7 reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and Nu226516: u00b1 [3% u00d7 (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability,
Average Acquisition Modevolts between any two averages of u226516 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source
CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHzTrigger Level Range
CH1/CH2: u00b18 divisions from center of screen;
EXT: u00b11.2V;
EXT/5:u00b16VTrigger Level Accuracy( typical)Accuracy is for signals having rise and fall times u226520ns
CH1/CH2: 0.2div u00d7 volts/div within u00b14 divisions from center of screen;
EXT: u00b1 (6% of setting + 40mV);
EXT/5: u00b1 (6% of setting + 200mV);Set Level to 50%(typical)
Operates with input signals u226550Hz
Video Trigger
Video Trigger Type
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2VSignal Formats and Field Rates, Video Trigger Type
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range
100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode
Trigger when (< , >, = , or u2260); Positive pulse or Negative pulse
Pulse Width Trigger Point
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse WidthPulse Width Range
20ns ~ 10s
Slope Trigger
Slope Trigger Mode
Trigger when (< , > , = , or u2260 ); Positive slope or Negative slope
Slope Trigger Point
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.Time Range
20ns ~ 10s
Overtime Trigger
Over Time Mode
Rising edge or Falling edge
Time Range
20ns ~ 10s
Alternative Trigger
Trigger on CH1
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2
Tools, Industrial & Scientific Ranking